Compilation for ul u438 2 hour wall assembly
SECTION 09 29 00, GYPSUM BOARD

Typical shaft wall assembly. 4. Typical fire rated ... B. Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: blue12
System Design Considerations

U415 or U438). For a single-layer both sides, two-hour wall,apply 1/2 SHEETROCK ... 2 A A Section AA Wall assemblyUL System No. W-L-1027 (metal pipe); F ...

Filetype:
Submitter: johnrsenior
EWB-W142 Shaft Wall

... Liner Panels or U438 wt. 8 ... to studs, the assembly provides 2-hour fire ... 37 CGC Shaft Wall Systems System BULC Design W452, or W506, or UL Design U415, 2 hour fire ...

Filetype:
Submitter: bestlipspeople
GYPSUM BOARD SHAFT WALL SYSTEMS - SECTION 09275

A. Vertical Shaft Wall Assembly; System B: 1. UL Design U438, 2 hr, STC 39. Framing - steel studs 24 in. oc. Shaftside - vertical liner panels positioned into studs ...

Filetype:
Submitter: marcierlsbshl
SECTION 092900 - GYPSUM BOARD

CAVITY SHAFT WALL. Coordinate assembly with Section 09 22 16 ... Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: ebookebook
Gypsum Board Partitions - Steel Framing STC - 38 OSU T-3296 WP ...

Chase wall, 5/8 (15.9 mm) Fire-Shield Gypsum Board applied vertically ... 2 Hour FIRE Design # UL U411 GA File # WP 1548 STC - 56 Sound Test # NGC-3022

Filetype:
Submitter: larry64016
SECTION 09 22 16, NON-STRUCTURAL METAL FRAMING

Typical shaft wall assembly . 4. Typical fire rated assembly and ... 3.5 INSTALLING SHAFT WALL SYSTEM . A. Conform to UL Design No. U438 for two hour fire rating.

Filetype:
Submitter: ruppygoneelycle
SUPPLEMENTARY INSTALLATION INSTRUCTIONS UL CLASSIFIED CURTAIN TYPE ...

1 1/2 HOUR LABEL, VERTICAL MOUNT ... for metal stud framing in UL resistant cavity shaft wall designs (1 and 2 hr.) including Nos. U438 ... assembly. 2. Damper Sleeve: Sleeve gauge ...

Filetype:
Submitter: mivyeasersser
VAMC PROJECT NUMBER: 688-08-048 WASHINGTON, DC

2. Typical sound rated assembly, showing treatment at ... B. Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: peegeinjemi
SA100 - Fire-Resistant Assemblies

Area Separation Wall Systems A 2 Hour Fire-rated ... 2-1/2 USG C-H Studs 25 gauge 24 o.c. or U438 1 SHEETROCK Brand ... Forming Joint Move- Comp- Assembly UL Reference or Wall ...

Filetype:
Submitter: funmonkey543
SECTION 09 29 00, GYPSUM BOARD

Typical shaft wall assembly. 4. Typical fire rated ... B. Conform to UL Design No. U438 or FM WALL CONSTRUCTION 12-2/HR (Nonbearing for two-hour fire rating.

Filetype:
Submitter: key-li
Shaft Wall

2-1/2 USG C-H Studs 25 gauge 24 o.c. or U438 ... 15 USG Shaft Wall Systems 2-Hour ... with a two-hour fire rating per UL Design U529. This shaft assembly is ...

Filetype:
Submitter: tommast
fire bulletin 2

tested and classified 1, 1 and 2-hour ... All openings between top of wall and roof deck are to be filled with UL ... wall assembly, including the axial design load of ...

Filetype:
Submitter: jorsulak